Paper
27 December 1977 Comparison Of Translate-Rotate And Pure Rotary Computed Tomography (CT) Body Scanners
D. P. Boyd, A. R. Margulis, M. Korobkin
Author Affiliations +
Proceedings Volume 0127, Application of Optical Instrumentation in Medicine VI; (1977) https://doi.org/10.1117/12.955951
Event: Application of Optical Instrumentation in Medicine VI, 1977, Boston, United States
Abstract
Two types of fast fan-beam CT body scanners are in widespread clinical use. A bi-modal type employs a series of linear translations followed by rotational steps. Rotary scanners use pure rotary motion of the source and detector or source alone (stationary detector type). We have conducted comparison studies using production models of an EMI-5005 and a GE CT/T installed at the Department of Radiology, U.C.S.F. These include quantitative determinations of noise and resolution, semiquantitative comparisons using phantoms, and qualitative evaluation of CT images obtained from double-scanned patients. Image quality of the two machines is roughly comparable under normal use. The most important differences involve the frequency and character of artifacts. The smoothness and speed of the rotary system's scanning motion greatly reduces that systems sensitivity to patient-motion-related streak artifacts. On the other hand the translate-rotate system currently offers higher spatial resolution and optional slow, high-dose, high-sensitivity scans.
© (1977) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
D. P. Boyd, A. R. Margulis, and M. Korobkin "Comparison Of Translate-Rotate And Pure Rotary Computed Tomography (CT) Body Scanners", Proc. SPIE 0127, Application of Optical Instrumentation in Medicine VI, (27 December 1977); https://doi.org/10.1117/12.955951
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scanners

Computed tomography

Electromagnetic coupling

Spectral resolution

Spatial resolution

Sensors

Aluminum

RELATED CONTENT

A Comparison Of The Number Of Rays Vs The Number...
Proceedings of SPIE (December 27 1977)
A Comparison Of Some Models Of X-Ray Beam Hardening
Proceedings of SPIE (December 23 1976)
Evaluation Of Computed Tomographic Units
Proceedings of SPIE (July 06 1979)
Optimizing Computed Tomography (CT) Scanner Geometry
Proceedings of SPIE (July 06 1979)
Engineering Status Of Computerized-Tomographic Scanning
Proceedings of SPIE (December 23 1976)

Back to Top