Abstract
Robotic CT is a novel imaging platform built on two manipulators with great flexibility and convenience. But it suffers from limited mechanical motion accuracy, which brings artifacts into images. Acquiring true geometry parameters is critical for accurate image reconstruction. While it’s impractical to monitor all geometry positions in practice. Down-sampling the projection number and using sparsity reconstruction offers a feasible way of solving this problem. Score-based generative model (SGM) is a powerful generative model able to produce directional samples guided by prior information. Through combining prior data and generated data, images quality can be significantly improved. In this work, we trained a score-based generative model using images from two real CT scan datasets. In sampling of score-based net, prior sparsity projection was added through cone-beam projection and image reconstruction. Full projection under non-standard geometry was simulated by adding deviation into standard circular geometry. We compared performance of several algorithms on sparsity and full data, under true and ideal geometry. Image was evaluated by typical indexes and visible details. Images of SART under ideal geometry showed severe artifacts, with strip artifacts in soft tissue. Compared with images under ideal geometry, SGM-based sparsity reconstruction showed visual fuzzier image but with higher index, which improved by 59.0% and 41.1% for PSNR and SSIM. Compared with sparsity reconstruction under true geometry using SART, SGM-based method showed clearer image and higher indexes, with 11.4% and 24.7% improvement of PSNR and SSIM. SGM-based sparsity reconstruction showed great potential in sparsity reconstruction under non-standard geometry.
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Xuan Zhou, Qiong Xu, Yuedong Liu, Cunfeng Wei, and Long Wei "SGM-based sparsity reconstruction under non-standard geometry of robotic CT", Proc. SPIE 12925, Medical Imaging 2024: Physics of Medical Imaging, 1292524 (1 April 2024); https://doi.org/10.1117/12.3006170
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image restoration

Computed tomography

Robotics

Education and training

Data modeling

Image processing

Sensors

Back to Top