Paper
1 September 1991 Progress in fiber-remote gas correlation spectrometry
John P. Dakin, Henry O. Edwards
Author Affiliations +
Proceedings Volume 1510, Chemical and Medical Sensors; (1991) https://doi.org/10.1117/12.47134
Event: ECO4 (The Hague '91), 1991, The Hague, Netherlands
Abstract
This paper reports on progress on gas sensing using real-time correlation spectroscopy, where a gas is used to 'recognize' its own spectral absorption lines. Our recent results on methane detection using pressure modulation spectrometry are shown, and a new method of modulating the absorption of the gas in the reference cell section of an ammonia detection system is reported for the first time. The basic concept of correlation spectrometry involves the passage of light sequentially through two gas cells, a reference cell containing a known quantity of the gas to be detected, and a sampling cell where the presence of the gas is to be determined. An optical signal passing sequentially through the cells will suffer absorption in each of the cells. If the absorption in the reference cell is periodically modulated, then the total absorption depends on whether the gas absorption lines in the sampling cell correlate with those in the reference cell gas. If the absorption lines of the gases do not correlate strongly, then the modulation index of the optical signal is essentially unaffected by the presence of the different gas in the sampling cell. Therefore, the concentration of a specific gas in the sampling cell can be quantified by this means. Pressure modulation of the gas within the reference cell is achieved by the use of a novel acoustic resonator. This device provides a reasonable pressure ratio while being compact and easily driven. Unlike previous piston-compressors, the high modulation frequency of the resonator improves the tolerance to transients in the optical signal produced by the passage of dust through the optical beam. The system can be tailored to detect a desired gas by changing the reference gas and a broadband section filter. Results for methane are presented in this paper. A novel method for detection of ammonia gas is reported for the first time. This involves Stark modulation of the gas in the reference cell, by the application of an electric field. This method is applicable to gases with strong electric dipole moments, such as NH3, CO, NOx, and HC1.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
John P. Dakin and Henry O. Edwards "Progress in fiber-remote gas correlation spectrometry", Proc. SPIE 1510, Chemical and Medical Sensors, (1 September 1991); https://doi.org/10.1117/12.47134
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation

Absorption

Methane

Sensors

Gases

Spectroscopy

Gas sensors

Back to Top