Paper
7 May 1996 Photoablation in atherosclerotic plaque at 9.5 μm with the free-electron laser FELIX
Benedikt J. Jean M.D., Rudolf Walker, Manfred Ostertag, Thomas Bende, M. Wehrmann, Lex van der Meer, Karl R. Karsch
Author Affiliations +
Abstract
So far, laser angioplasty in minimally invasive cardiac surgery has been performed with the Excimer laser in the UV, and experimentally with IR lasers, at 2.1 micrometers (Holmium laser) and 2.94 micrometers (Erbium laser), using water as the prevailing absorber. Plaques are inhomogeneous, composed of various materials (fibrous tissue, cholesterol, hydroxyapatite calcifications) absorbing off the water absorption bands. The Free-Electron Laser FELIX (FOM, Nieuwegein/NL) was tuned to 9.5 micrometers wavelength (absorption maximum of hydroxyapatite and cholesterol) and to wavelengths with low absorption in plaque. Ablation was performed in vitro at an energy per pulse between 10 and 20 mJ and a laserpulse length (macropulse) of 4 micrometers . Ablation rates, ablation thresholds and collateral thermal damage were assessed by histologic micrometry for plaque and for normal vessel wall. The ablation rates were found to be higher in water containing plaque than in calcified plaque. With the high absorption of hydroxyapatite at 9.5 micrometers , the ablation thresholds for (calcified) plaque and vessel wall differ by 50% at least. Thus, accidental perforation is almost impossible, adding an element of selectivity and inherent safety not available so far. Collateral thermal damage at all applied wavelengths was of the same order as known from other IR sources (15 - 30 micrometers ).
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Benedikt J. Jean M.D., Rudolf Walker, Manfred Ostertag, Thomas Bende, M. Wehrmann, Lex van der Meer, and Karl R. Karsch "Photoablation in atherosclerotic plaque at 9.5 μm with the free-electron laser FELIX", Proc. SPIE 2681, Laser-Tissue Interaction VII, (7 May 1996); https://doi.org/10.1117/12.239581
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Absorption

Free electron lasers

Laser ablation

Laser therapeutics

Tissues

Safety

Excimer lasers

RELATED CONTENT

Lasers in oral surgery and implantology
Proceedings of SPIE (March 22 2016)
Laser Surgery: Alternatives To CO2 Ablation
Proceedings of SPIE (November 20 1985)
Erbium laser in middle ear surgery: laboratory study
Proceedings of SPIE (September 07 1994)

Back to Top