11 November 1996 Calibration aspects of remote sensing spaceborne spectrometers
Henri G.C. Werij, Bob Kruizinga, Carina Olij, Roel Hoekstra
Author Affiliations +
Abstract
To gain insight in the dynamics and the long-term behavior of constituents (e.g., ozone, CFCs) of the Earth atmosphere, satellite-based instruments allowing global monitoring provide unsurpassed information. In order to study atmospheric trends over a very long period of time, these instruments generally have to be calibrated normalized to the sun very accurately. Furthermore, the accuracy has to be maintained during the lifetime of the instruments. This contribution addresses the issue of radiometric calibration of earth-observation instruments, both on ground and in flight. Some of the related issues will be illustrated by focusing on two specific instruments (to be) calibrated at TPD: the global ozone monitoring experiment (GOME), which was launched on ERS-2 in April 1995, and the scanning imaging absorption spectrometer for atmospheric cartography (SCIAMACHY), to be launched on Envisat around the turn of the century. We distinguish between sun-normalized calibration and absolute radiometric calibration. In both cases instrument sensitivity to polarization is a complicating factor. Other factors to be dealt with are, e.g., the etalon effect and the influence of humidity during on-ground calibration. These all require a sophisticated calibration approach and well-adapted radiometric calibration equipment. After on-ground calibration the instruments are susceptible to possible changes or degradation. Therefore, GOME and SCIAMACHY both contain a well-calibrated on-board diffuser providing an accurate reflectance standard. However, this diffuser itself is degrading with time due to contamination and radiation effects. An in-flight monitoring concept is therefore mandatory. The addressed calibration aspects are elucidated using the example of SCIAMACHY.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Henri G.C. Werij, Bob Kruizinga, Carina Olij, and Roel Hoekstra "Calibration aspects of remote sensing spaceborne spectrometers", Proc. SPIE 2820, Earth Observing System, (11 November 1996); https://doi.org/10.1117/12.258095
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Diffusers

Sensors

Polarization

Sun

Mirrors

Spectrometers

RELATED CONTENT

Calibration of GOME-2 data
Proceedings of SPIE (December 18 2002)
Calibration approach for SCIAMACHY
Proceedings of SPIE (September 18 1997)
Pre- and in-flight calibration of GOME
Proceedings of SPIE (January 27 1997)

Back to Top