Paper
7 June 1999 Development of rotating-disk singlet-generator-based kilowatt-level COIL
Amitav Mallik, A. L. Dawar, Y. L. N. Murthy, K. Kohli, A. K. Badola, Anil K. Razdan
Author Affiliations +
Abstract
Various essential parameters like mass transfer coeff, volumetric flow rates etc. for a typical KW level COIL have been considered and the gas residence time and thus the size of the SOG has been estimated. The SOG based on this design has been fabricated and is under evaluation. The design of SOG and various other subsystems like nozzles, resonator and liquid nitrogen trap have been discussed in this paper. Further systematic studies have been carried out on the shelf life of basic hydrogen peroxide (BHP) in the temperature range of -10°C to +10°C using titration technique. Studies indicate that the solution prepared at -10°C to -15°C and stored at this temperature, the decomposition starts only after 36-42 hours. However, at higher storage temperatures, the decomposition is faster.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Amitav Mallik, A. L. Dawar, Y. L. N. Murthy, K. Kohli, A. K. Badola, and Anil K. Razdan "Development of rotating-disk singlet-generator-based kilowatt-level COIL", Proc. SPIE 3612, Gas and Chemical Lasers and Intense Beam Applications II, (7 June 1999); https://doi.org/10.1117/12.350644
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Chlorine

Chemical oxygen iodine lasers

Oxygen

Chemical lasers

Chlorine gas

Liquids

Resonators

RELATED CONTENT


Back to Top