22 October 1999 Design and performance of the ASTRO-E/XRS microcalorimeter array and anticoincidence detector
Author Affiliations +
Abstract
The XRS instrument has an array of 32 micro-calorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of 9 eV at 3 keV and 11 eV at 6 keV. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, operating temperature, thermistor size, absorber choice, and means of attaching the absorber to the thermistor bearing element. We will present representative performance data, though a more detailed presentation of the results of the instrument calibration is presented elsewhere in these proceedings. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance in conjunction with the array.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Caroline A. Kilbourne, Michael Damian Audley, Kevin R. Boyce, Regis P. Brekosky, Ryuichi Fujimoto, Keith C. Gendreau, John D. Gygax, Yoshitaka Ishisaki, Richard L. Kelley, R. A. McClanahan, Tatehiro Mihara, Kazuhisa Mitsuda, Samuel Harvey Moseley Jr., David Brent Mott, Frederick Scott Porter, Carl Michael Stahle, and Andrew E. Szymkowiak "Design and performance of the ASTRO-E/XRS microcalorimeter array and anticoincidence detector", Proc. SPIE 3765, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy X, (22 October 1999); https://doi.org/10.1117/12.366494
Lens.org Logo
CITATIONS
Cited by 20 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Silicon

X-rays

Resistance

Field effect transistors

Particles

Calibration

Back to Top