Paper
5 August 2002 QWIP LWIR cameras with NETD<10 mK and improved low-frequency drift for long observation time in medicine and research
Author Affiliations +
Abstract
Low NETD's, coupled with other improvements in camera design and manufacturing, helps to further enable a new class of very demanding imaging applications in medicine and medical research.. The evolution of QWIP FPA over the past five years, with their low NETD, detector uniformity, and high pixel yield, along with improvements in camera control and processing electronics, represents key technical innovations responsible for the reemergence of medical infrared imaging through the development of a new infrared medical imaging technique called Dynamic Infrared Imaging or DIRI. The QWIP's high thermal and spatial resolution coupled with very fast data acquisition capabilities fill the essential requirements of DIRI. Other features required by DIRI applications are the need for stable operation with drifts in the image below a few mK, which allow longer data collecting time. Longer data collection time provides the camera the capability to detect the functional behavior of the autonomic nervous system which operates on a time scale of 0.1 to 0.2Hz.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Wolfgang A. Cabanski, Rainer Breiter, Werner Rode, Johann Ziegler, Harald Schneider, Martin Walther, and Mark A. Fauci "QWIP LWIR cameras with NETD<10 mK and improved low-frequency drift for long observation time in medicine and research", Proc. SPIE 4721, Infrared Detectors and Focal Plane Arrays VII, (5 August 2002); https://doi.org/10.1117/12.478843
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Quantum well infrared photodetectors

Cameras

Infrared imaging

Thermography

Medical imaging

Imaging systems

Infrared radiation

RELATED CONTENT

Infrared camera based on optical-readout bi-material FPA
Proceedings of SPIE (September 08 2011)
A brief history of 25 years (or more) of infrared...
Proceedings of SPIE (April 01 2003)
Infrared vision using uncooled optomechanical camera
Proceedings of SPIE (April 13 2000)
Helicopter-borne dual-band dual-FPA system
Proceedings of SPIE (October 10 2003)
Improved integrated sniper location system
Proceedings of SPIE (January 07 1999)

Back to Top