11 October 2004 Ground calibration of CCD camera (XIS) with front-illuminated chips onboard Astro-E2
Author Affiliations +
Abstract
We report on the results of the ground calibration of Astro-E2/XIS with front-illuminated (FI) chips. The sensors have basically the same performance as that of Astro-E/XIS. However, there are some improved points: (1) A 55Fe radio isotope is equipped on a door, and (2) a charge injection (CI)capability (described below) is added. The FI sensors have been calibrated at Kyoto University, Osaka University, and MIT. At Kyoto University we focus on the high energy range (>1.5 keV). We measured the gain, energy resolution, and quantum efficiency as the function of energy by using characteristic X-rays for each sensor. An energy resolution of 130 eV@5.9 keV (FWHM) and a quantum efficiency of 82%@6.4 keV are achieved. After XIS is launched, the Charge Transfer Inefficiency (CTI) increases due to the radiation damage by cosmic rays. Then XIS equips the CI capability to calibrate and compensate the increase of the CTI. In order to utilize the CI capability, the amount of charge injected into the CCDs is expected to be kept constant. The time variability of the amount of the injected charge is estimated.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hiroshi Nakajima, Hiroya Yamaguchi, Hironori Matsumoto, Takeshi Tsuru, Katsuji Koyama, Steve Kissel, Beverly LaMarr, and Marshall W. Bautz "Ground calibration of CCD camera (XIS) with front-illuminated chips onboard Astro-E2", Proc. SPIE 5488, UV and Gamma-Ray Space Telescope Systems, (11 October 2004); https://doi.org/10.1117/12.550831
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

Calibration

Charge-coupled devices

Quantum efficiency

Iron

Bismuth

RELATED CONTENT

Characterization of the CCDs for the Joint European X Ray...
Proceedings of SPIE (November 11 1994)
X-ray CCD calibration for the AXAF CCD Imaging Spectrometer
Proceedings of SPIE (November 19 1998)
X-ray CCD calibration for the AXAF CCD Imaging Spectrometer
Proceedings of SPIE (October 31 1996)
CUBIC: preflight calibration status
Proceedings of SPIE (September 01 1995)

Back to Top