Paper
20 April 2005 Four-arm variable-resolution x-ray detector for CT target imaging
Frank A. DiBianca, Daya Gulabani, Lawrence M. Jordan, Sravanthi Vangala, David Rendon, Joseph S. Laughter, Roman Melnyk, M. Waleed Gaber, Gary S. Keyes
Author Affiliations +
Abstract
The basic VRX technique boosts spatial resolution of a CT scanner in the scan plane by two or more orders of magnitude by reducing the angle of incidence of the x-ray beam with respect to the detector surface. A four-arm Variable-Resolution X-ray (VRX) detector has been developed for CT scanning. The detector allows for "target imaging" in which an area of interest is scanned at higher resolution than the remainder of the subject, yielding even higher resolution for the focal area than that obtained from the basic VRX technique. The new VRX-CT detector comprises four quasi-identical arms each containing six 24-cell modules (576 cells total). The modules are made of individual custom CdWO4 scintillators optically-coupled to custom photodiode arrays. The maximum scan field is 40 cm for a magnification of 1.4. A significant advantage of the four-arm geometry is that it can transform quickly to the two-arm, or even the single-arm geometry, for comparison studies. These simpler geometries have already been shown experimentally to yield in-plane CT detector resolution exceeding 60 cy/mm (<8μ) for small fields of view. Geometrical size and resolution limits of the target VRX field are calculated. Two-arm VRX-CT data are used to simulate and establish the feasibility of VRX CT target imaging. A prototype target VRX-CT scanner has been built and is undergoing initial testing.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Frank A. DiBianca, Daya Gulabani, Lawrence M. Jordan, Sravanthi Vangala, David Rendon, Joseph S. Laughter, Roman Melnyk, M. Waleed Gaber, and Gary S. Keyes "Four-arm variable-resolution x-ray detector for CT target imaging", Proc. SPIE 5745, Medical Imaging 2005: Physics of Medical Imaging, (20 April 2005); https://doi.org/10.1117/12.594102
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-ray detectors

Target detection

X-rays

X-ray computed tomography

Spatial resolution

Image resolution

RELATED CONTENT

Photon counting CT at elevated X ray tube currents ...
Proceedings of SPIE (March 19 2014)
Soil matrix study using a hybrid a Se CMOS pixel...
Proceedings of SPIE (October 17 2022)
Evaluation of x ray detectors for dual modality CT SPECT...
Proceedings of SPIE (November 26 2002)
Ultrahigh-resolution CT and DR scanner
Proceedings of SPIE (May 28 1999)
Design and evaluation of a prototype volume CT scanner
Proceedings of SPIE (April 20 2005)

Back to Top