Paper
7 March 2006 In vivo autofluorescence lifetime imaging at the fundus of the human eye
Dietrich Schweitzer, Martin Hammer, Frank Schweitzer, Stefan Schenke, Eckhard Birckner, Wolfgang Becker, Axel Bergmann
Author Affiliations +
Proceedings Volume 6138, Ophthalmic Technologies XVI; 613808 (2006) https://doi.org/10.1117/12.644692
Event: SPIE BiOS, 2006, San Jose, California, United States
Abstract
Changes in cellular metabolism are considered first signs of fundus diseases, e.g. of age-related macular degeneration. Changes in the metabolism can potentially be detected by measuring the autofluorescence of the fundus. The fundus contains a wide variety of fluorophores in different binding and quenching states. The fluorescence signals cannot be clearly discriminated by commonly used steady state imaging techniques, even when these are combined with spectral resolution and excitation wavelength multiplexing. A considerable improvement is obtained by fluorescence lifetime imaging (FLIM). FLIM not only adds an additional discrimination parameter to distinguish different fluorophores but also resolves different quenching states of the same fluorophore. Due to its high sensitivity and high time resolution, its capability to resolve multi-exponential decay functions, and its easy combination with fast scanning we use multi-dimensional time-correlated single photon counting for fundus imaging. By analyzing the spectral properties of the expected fluorophores in the fundus, we show that improved discrimination of fluorophores is obtained by FLIM in combination with selected excitation wavelength and emission wavelength. As demonstrated in lifetime histograms of 40° fundus images, several fluorophores are excited at 446 nm, but predominantly lipofuscin at 468 nm excitation. Simultaneous detection of lifetime images in two emission ranges 500 nm to 560 nm and 560 nm to 700 nm improves further the discrimination of fluorophores.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dietrich Schweitzer, Martin Hammer, Frank Schweitzer, Stefan Schenke, Eckhard Birckner, Wolfgang Becker, and Axel Bergmann "In vivo autofluorescence lifetime imaging at the fundus of the human eye", Proc. SPIE 6138, Ophthalmic Technologies XVI, 613808 (7 March 2006); https://doi.org/10.1117/12.644692
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Luminescence

Picosecond phenomena

Eye

Fluorescence lifetime imaging

Mode conditioning cables

In vivo imaging

Laser scanners

Back to Top