20 March 2006 Improvement of image quality in MDCT by high-frequency sampling of x-, y- and z-direction
Author Affiliations +
Abstract
The multi-detector row computed tomography (MDCT) has dramatically increased speed of scanning, and allows high-resolution imaging compared with the conventional single-detector row CT (SDCT). However, use of the MDCT was making use of three-dimensional (3D) volume scanning and four-dimensional (4D) dynamic scanning increase, and made radiation dose to patients increase simultaneously. In addition, in recent years, lung-cancer screening CT (LSCT) is introduced, and low-dose scanning is strongly required to increase the benefit/risk ratio. In this study, high-frequency volume data sampling (over-sampling) method of x-, y- and z-direction was proposed as technique for reduction of image noise in the MDCT and discussed about reduction of radiation dose and improvement of image quality. In this proposed method, volume data are obtained by over-sampling of x-, y- and z-direction and image is obtained by averaging these data. In x- and y-direction, over-sampling is equivalent to obtaining projection data using large matrix size for same scan-field of view (scan-FOV), and in z-direction, equivalent to using thin slice. Normally, when signal with which noise distribution differs are averaged n-times, signal-to-noise ratio (SNR) will increases by factor of [square root of] n. In this method, each pixel value of the image is obtained from n2x,ynz pixels by nx,y-times sampling for x- and y-direction, and nz-times sampling for z-direction. In other words, SNR of the image increases [square root of] n2x,ynz-times. In this high-frequency data sampling method, it is possible to obtain high-quality image as compared with conventional image. Moreover, by applying to noisy image obtained with low-dose scanning, reduction of radiation dose to patients is possible.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Naruomi Yasuda, Yoko Ishikawa, and Yoshie Kodera "Improvement of image quality in MDCT by high-frequency sampling of x-, y- and z-direction", Proc. SPIE 6144, Medical Imaging 2006: Image Processing, 61446C (20 March 2006); https://doi.org/10.1117/12.652964
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image processing

Sensors

Signal to noise ratio

Image quality

Computed tomography

Denoising

3D image processing

Back to Top