29 January 2007 High-sensitive radiography system utilizing a pulse x-ray generator and a night-vision CCD camera (MLX)
Eiichi Sato, Michiaki Sagae, Etsuro Tanaka, Hidezo Mori, Toshiaki Kawai, Takashi Inoue, Akira Ogawa, Shigehiro Sato, Toshio Ichimaru, Kazuyoshi Takayama
Author Affiliations +
Proceedings Volume 6279, 27th International Congress on High-Speed Photography and Photonics; 627941 (2007) https://doi.org/10.1117/12.725351
Event: 27th International congress on High-Speed Photography and Photonics, 2006, Xi'an, China
Abstract
High-sensitive radiography system utilizing a kilohertz-range stroboscopic x-ray generator and a night-vision CCD camera (MLX) is described. The x-ray generator consists of the following major components: a main controller, a condenser unit with a Cockcroft-Walton circuit, and an x-ray tube unit in conjunction with a grid controller. The main condenser of about 500 nF in the unit is charged up to 100 kV by the circuit, and the electric charges in the condenser are discharged to the triode by the grid control circuit. The maximum tube current and the repetition rate are approximately 0.5 A and 50 kHz, respectively. The x-ray pulse width ranges from 0.01 to 1.0 ms, and the maximum shot number has a value of 32. At a charging voltage of 60 kV and a width of 1.0 ms, the x-ray intensity obtained without filtering was 6.04 μGy at 1.0 m per pulse. In radiography, an object is exposed by the pulse x-ray generator, and a radiogram is taken by an image intensifier. The image is intensified by the CCD camera, and a stop-motion image is stored by a flash memory device using a trigger delay device. The image quality was improved with increases in the x-ray duration, and a single-shot radiography was performed with durations of less than 1.0 ms.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eiichi Sato, Michiaki Sagae, Etsuro Tanaka, Hidezo Mori, Toshiaki Kawai, Takashi Inoue, Akira Ogawa, Shigehiro Sato, Toshio Ichimaru, and Kazuyoshi Takayama "High-sensitive radiography system utilizing a pulse x-ray generator and a night-vision CCD camera (MLX)", Proc. SPIE 6279, 27th International Congress on High-Speed Photography and Photonics, 627941 (29 January 2007); https://doi.org/10.1117/12.725351
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Radiography

X-ray imaging

CCD cameras

Cameras

Image quality

Imaging systems

RELATED CONTENT

X-ray counting imaging based on spherical collimation
Proceedings of SPIE (November 15 2017)
X-ray imaging using digital cameras
Proceedings of SPIE (March 03 2012)
X-Ray Image Intensifiers
Proceedings of SPIE (March 01 1974)

Back to Top