14 February 2007 Noninvasive blood glucose measurement using multiple laser diodes
E. T. Ooi, X. Q. Zhang, J. H. Chen, P. H. Soh, K. Ng, J. H. Yeo
Author Affiliations +
Abstract
In the event of diabetes clinicians have advocated that frequent monitoring of a diabetic's blood glucose level is the key to avoid future complications (kidney failure, blindness, amputations, premature death, etc.,) associated with the disease. While the test-strip glucose meters available in current consumer markets allow for frequent monitoring, a more convenient technique that is accurate, painless and sample-free is preferable in a diabetic's daily routine. This paper presents a non-invasive blood glucose measurement technique using diffuse reflectance near infrared (NIR) signals. This technique uses a set of laser diodes, each operating at fixed wavelengths in the first overtone region. The NIR signals from the laser diodes are channeled to the measurement site viz., the nail-bed by means of optical fibers. A series of in vivo experiments have been performed on eight normal human subjects using a standard Oral Glucose Tolerance Test (OGTT) protocol. The reflected NIR signals are inputs to a Partial Least Squares (PLS) algorithm for calibration and future predictions. The calibration models used are developed using in vivo datasets and are unique to a particular individual. The 1218 paired points collected from the eight test subjects plotted on the Clarke Error Grid, revealed that 87.3% of these points fall within the A zone while the remainder, within the B zone, both of which, are clinically accepted. The standard error of prediction was ±13.14mg/dL for the best calibration model. A Bland-Altman analysis of the 1218 paired points yields a 76.3% confidence level for a measurement accuracy of ±20mg/dL. These results demonstrate the initial potential of the technique for non-invasive blood glucose measurements in vivo.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
E. T. Ooi, X. Q. Zhang, J. H. Chen, P. H. Soh, K. Ng, and J. H. Yeo "Noninvasive blood glucose measurement using multiple laser diodes", Proc. SPIE 6445, Optical Diagnostics and Sensing VII, 64450K (14 February 2007); https://doi.org/10.1117/12.698881
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications and 21 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Glucose

Blood

Near infrared

Calibration

Semiconductor lasers

Optical fibers

In vivo imaging

Back to Top