Paper
14 September 2007 An analytical method for measuring the decentration of lens module
Author Affiliations +
Abstract
In this paper, an analytic procedure has been developed for the root cause identification of the lens module decentration. By analyzing the lens module according to a predetermined analysis process to generate analysis parameters corresponding to the lens module, and measured performance data can then be compared with these simulated data for validation. This can reveals very valuable information to help fine tune the injection mold.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Chir-Weei Chang "An analytical method for measuring the decentration of lens module", Proc. SPIE 6671, Optical Manufacturing and Testing VII, 667116 (14 September 2007); https://doi.org/10.1117/12.730598