Paper
29 February 2008 Frequency-domain inverse Monte Carlo simulation for the diagnosis of the early cervical cancer based on NIR diffuse measurement
Huijuan Zhao, Shunqi Zhang, Zhaoxia Wang, Hui Miao, Zhen Du, Jingying Jiang
Author Affiliations +
Abstract
This article aims at the optical parameter reconstruction technology for the frequency- domain measurement of near-infrared diffused light. For mimicking the cervix, a cylindrical model with hole in the middle is used in the simulation and experiments. Concerning the structure of the cervix, Monte-Carlo simulation is adopted for describing the photon migration in tissue and Perturbation Monte-Carlo is used for the reconstruction of the optical properties of cervix. The difficulties in the reconstruction of cervical optical properties with frequency domain measurement are the description of the tissue boundary, expression of the frequency-domain signal, and development of rapid reconstruction method for clinical use. To get the frequency domain signal in Monte Carlos simulation, discrete Fourier transformation of the photon migration history in time-domain is employed. By combining the perturbation Monte-Carlo simulation and the LM optimization technology, a rapid reconstruction algorithm is constructed, by which only one Monte-Carlo simulation is needed. The reconstruction method is validated by simulation and experiments on solid phantom. Simulation results show that the inaccuracy in reconstruction of absorption coefficient is less than 3% for a certain range of optical properties. The algorithm is also proved to be robust to the initial guess of optical properties and noise. Experimental results showed that the absorption coefficient can be reconstructed with inaccuracy of less than 10%. The absorption coefficient reconstruction for one set of measurement data can be fulfilled within one minute.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Huijuan Zhao, Shunqi Zhang, Zhaoxia Wang, Hui Miao, Zhen Du, and Jingying Jiang "Frequency-domain inverse Monte Carlo simulation for the diagnosis of the early cervical cancer based on NIR diffuse measurement", Proc. SPIE 6859, Imaging, Manipulation, and Analysis of Biomolecules, Cells, and Tissues VI, 68591N (29 February 2008); https://doi.org/10.1117/12.761510
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monte Carlo methods

Tissue optics

Absorption

Optical properties

Reconstruction algorithms

Cervical cancer

Cervix

Back to Top