Paper
12 March 2009 Analysis of probed regions in an interactive CAD system for the detection of masses in mammograms
M. Samulski, A. Hupse, C. Boetes, G. den Heeten, N. Karssemeijer
Author Affiliations +
Abstract
Most computer aided detection (CAD) systems for mammographic mass detection display all suspicious regions identified by computer algorithms and are mainly intended to avoid missing cancers due to perceptual oversights. Considering that interpretation failure is recognized to be a more common cause of missing cancers in screening than perceptual oversights, a dedicated mammographic CAD system has been developed that can be queried interactively for the presence of CAD prompts using a mouse click. To assess the potential benefit of using CAD in an interactive way, an observer study was conducted in which 4 radiologists and 6 non-radiologists evaluated 60 cases with and without CAD, to compare the detection performance of the unaided reader with that of the reader with CAD assistance. 20 cases had a malignant mass, and 40 were cancer-free. During the reading sessions we recorded time and probed locations which reveal information about the search strategy and detection process. The purpose of this study is to determine a relation between detection performance and time to first probe of the lesion and to investigate if longer reading times lead to more reports of malignant lesions in lesion-free areas. On average, 65.0% of the malignant lesions were found within 60 seconds and this percentage stabilizes after this period. Results suggest that longer reading time did not lead to more false positives. 74.6% of the reported true positive findings were hit by the first probe, and 93.2% were hit within 5 probes, which may suggest that many of the correctly reported malignant masses were perceived immediately after image onset.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
M. Samulski, A. Hupse, C. Boetes, G. den Heeten, and N. Karssemeijer "Analysis of probed regions in an interactive CAD system for the detection of masses in mammograms", Proc. SPIE 7263, Medical Imaging 2009: Image Perception, Observer Performance, and Technology Assessment, 726314 (12 March 2009); https://doi.org/10.1117/12.813391
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computer aided diagnosis and therapy

Mammography

Computer aided design

CAD systems

Cancer

Computing systems

Detection and tracking algorithms

Back to Top