Paper
10 August 2010 The data processing pipelines for the Herschel/SPIRE imaging Fourier transform spectrometer
Trevor R. Fulton, Jean-Paul Baluteau, George Bendo, Dominique Benielli, Rene Gastaud, Matt Griffin, Steve Guest, Peter Imhof, Tanya L. Lim, Nanyao Lu, David A. Naylor, Pasquale Panuzzo, Edward Polehampton, Arnold Schwartz, Christian Surace, Bruce M. Swinyard, Kevin Xu
Author Affiliations +
Abstract
We present an update to the data processing pipelines that generate calibrated spectral data products from the Spectral and Photometric Imaging Receiver (SPIRE), one of three scientific instruments onboard the European Space Agency's Herschel Space Observatory launched on 14 May 2009. The pipelines process telemetry from SPIRE's imaging Fourier Transform Spectrometer (FTS) taken in point source, jiggle- and raster-map observing modes, producing calibrated spectra in low-, medium-, high-, and mixed low- and high-spectral resolution. While the order and algorithms of the data processing modules in the spectrometer pipelines remain for the most part unchanged compared to their pre-launch status, some improvements and optimizations have been realized through the analysis of data from the performance verification and science demonstration phases of the mission. The data processing pipelines for the SPIRE FTS as of the beginning of the routine phase of the Herschel mission are presented in their entirety, with more detailed descriptions reserved for those elements that have changed since launch, in particular the first- and second-level correction steps for glitches, the step that corrects for clipped samples, and the process by which Level-1 spectral data are converted to Level-2 products. In addition, we discuss some of the challenging aspects still faced by the automated processing pipelines, such as the removal of the contributions from the Herschel telescope and SPIRE instrument, and the relative spectral response correction and flux conversion steps.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Trevor R. Fulton, Jean-Paul Baluteau, George Bendo, Dominique Benielli, Rene Gastaud, Matt Griffin, Steve Guest, Peter Imhof, Tanya L. Lim, Nanyao Lu, David A. Naylor, Pasquale Panuzzo, Edward Polehampton, Arnold Schwartz, Christian Surace, Bruce M. Swinyard, and Kevin Xu "The data processing pipelines for the Herschel/SPIRE imaging Fourier transform spectrometer", Proc. SPIE 7731, Space Telescopes and Instrumentation 2010: Optical, Infrared, and Millimeter Wave, 773134 (10 August 2010); https://doi.org/10.1117/12.858282
Lens.org Logo
CITATIONS
Cited by 17 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Spectroscopy

Sensors

Fourier transforms

Data processing

Signal detection

Space telescopes

Telescopes

Back to Top