Paper
23 February 2012 Automatic fetal weight estimation using 3D ultrasonography
Shaolei Feng, Kevin S. Zhou, Wesley Lee
Author Affiliations +
Abstract
This paper proposes a novel and fast approach for automatic estimation of the fetal weights from 3D ultrasound data. Conventional manual approaches are time-consuming and involve inconsistence by different sonographers because of the difficulty to trace limb boundaries in complicated Ultrasound limb volumes. It takes up to 10 minutes to manually trace the surface borders of a 20cm long limb. Using our automatic approach, the time is significantly reduced to 2.1 seconds for measuring the weights based on the entire limb. Experiments with the automatic approach also show comparable standard deviation and limits of agreement to the manual approaches.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Shaolei Feng, Kevin S. Zhou, and Wesley Lee "Automatic fetal weight estimation using 3D ultrasonography", Proc. SPIE 8315, Medical Imaging 2012: Computer-Aided Diagnosis, 83150I (23 February 2012); https://doi.org/10.1117/12.911736
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications and 2 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fetus

Ultrasonography

Tissues

Image segmentation

Bone

Sensors

Prototyping