Paper
26 September 2013 Development and first results of the Yale PIXeY two-phase xenon detector
Nicholas E. Destefano, Ethan Bernard, Blair Edwards, Moshe Gai, Markus Horn, Nicole Larsen, Daniel McKinsey, Brian Tennyson, Christopher Wahl
Author Affiliations +
Abstract
PIXeY (Particle Identification in Xenon at Yale) is a two-phase (liquid/gas) xenon prototype time projection chamber with 3 kg active mass. PIXeY was built to optimize energy resolution and gamma/neutron discrimination, with a number of technological improvements over previous work. Parallel-wire grids, which control the drift and proportionalscintillation fields, are optimized both for light collection efficiency and field uniformity. High quantum efficiency Hamamatsu R8778 PMTs, high-reflectivity Teflon walls, and charge-light anti-correlation techniques are also incorporated. The first run of the detector has concluded, where all systems were tested both using LED calibration methods as well as using sources for calibration and spectral measurements. Ultimately our results were limited by PMT calibration issues, low light collection caused by saturation, and low drift fields constrained by high voltage hardware. The second run of the detector is currently underway with several improved components. The feedthroughs for higher voltages have improved to allow a much higher operating voltage, new PMT bases for more stable operation have been installed, and three new grids with transparencies between 92% and 97% have been added. Once the energy resolution studies have concluded, PIXeY will serve as a platform for future improvements, including multiple optical volumes and single wire readout for R&D on gamma-ray imaging.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Nicholas E. Destefano, Ethan Bernard, Blair Edwards, Moshe Gai, Markus Horn, Nicole Larsen, Daniel McKinsey, Brian Tennyson, and Christopher Wahl "Development and first results of the Yale PIXeY two-phase xenon detector", Proc. SPIE 8852, Hard X-Ray, Gamma-Ray, and Neutron Detector Physics XV, 88520I (26 September 2013); https://doi.org/10.1117/12.2027678
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Xenon

Electrons

Chemical species

Data acquisition

Scintillation

Signal detection

RELATED CONTENT

Nature of EM waves as observed and reported by detectors...
Proceedings of SPIE (September 28 2011)
Spectroscopic capabilities of imaging GSPCs
Proceedings of SPIE (September 01 1995)
New optical method for water treatment control
Proceedings of SPIE (September 16 1999)
A method for calibrating PMTs in T0 system for beam...
Proceedings of SPIE (October 15 2010)

Back to Top