Paper
19 March 2014 Volume estimation of multi-density nodules with thoracic CT
Author Affiliations +
Abstract
The purpose of this work was to quantify the effect of surrounding density on the volumetric assessment of lung nodules in a phantom CT study. Eight synthetic multidensity nodules were manufactured by enclosing spherical cores in larger spheres of double the diameter and with a different uniform density. Different combinations of outer/inner diameters (20/10mm, 10/5mm) and densities (100HU/-630HU, 10HU/- 630HU, -630HU/100HU, -630HU/-10HU) were created. The nodules were placed within an anthropomorphic phantom and scanned with a 16-detector row CT scanner. Ten repeat scans were acquired using exposures of 20, 100, and 200mAs, slice collimations of 16x0.75mm and 16x1.5mm, and pitch of 1.2, and were reconstructed with varying slice thicknesses (three for each collimation) using two reconstruction filters (medium and standard). The volumes of the inner nodule cores were estimated from the reconstructed CT data using a matched-filter approach with templates modeling the characteristics of the multi-density objects. Volume estimation of the inner nodule was assessed using percent bias (PB) and the standard deviation of percent error (SPE). The true volumes of the inner nodules were measured using micro CT imaging. Results show PB values ranging from -12.4 to 2.3% and SPE values ranging from 1.8 to 12.8%. This study indicates that the volume of multi-density nodules can be measured with relatively small percent bias (on the order of ±12% or less) when accounting for the properties of surrounding densities. These findings can provide valuable information for understanding bias and variability in clinical measurements of nodules that also include local biological changes such as inflammation and necrosis.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Marios A. Gavrielides, Qin Li, Rongping Zeng, Kyle J. Myers, Berkman Sahiner, and Nicholas Petrick "Volume estimation of multi-density nodules with thoracic CT", Proc. SPIE 9033, Medical Imaging 2014: Physics of Medical Imaging, 903331 (19 March 2014); https://doi.org/10.1117/12.2043833
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computed tomography

Collimation

Lung

Image processing

Biological research

Inflammation

Data modeling

Back to Top