Paper
6 April 2015 Simulation study of the influence of PEB reaction rates on resist LER
Author Affiliations +
Abstract
A stochastic resist simulator has first been calibrated to experimental results performed on a commercially available EUV resist, and subsequently has been used to study the influence of acid/base quenching rate and the polymer deprotection rate on resist LER for 22 nm half-pitch lines/spaces. Results indicate that larger quenching rates and smaller deprotection rates result in improved LER performance by causing an increase in the dose to size. With nominal quenching rate determined from literature, halving the deprotection rate relative to nominal value reduces the LER by 33%, while the dose to size increases by 2x. With nominal deprotection rate determined from literature, results indicate a low sensitivity of LER to quenching rate. Expected noise at the line edge calculated by using a shot noise model accounting for absorbed photons, acid, and base count, provides a good explanation for the LER trends calculated for several reaction rate scenarios.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Suchit Bhattarai, Andrew R. Neureuther, and Patrick P. Naulleau "Simulation study of the influence of PEB reaction rates on resist LER", Proc. SPIE 9422, Extreme Ultraviolet (EUV) Lithography VI, 94222I (6 April 2015); https://doi.org/10.1117/12.2087566
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Line edge roughness

Calibration

Extreme ultraviolet

Photons

Point spread functions

Quenching (fluorescence)

Stochastic processes

RELATED CONTENT