23 October 2015 Quantifying cross-scatter contamination in biplane fluoroscopy motion analysis systems
Janelle A. Cross, Ben McHenry, Taly G. Schmidt
Author Affiliations +
Abstract
Biplane fluoroscopy is used for dynamic in vivo three-dimensional motion analysis of various joints of the body. Cross-scatter between the two fluoroscopy systems may limit tracking accuracy. This study measured the magnitude and effects of cross-scatter in biplane fluoroscopic images. Four cylindrical phantoms of 4-, 6-, 8-, and 10-in. diameter were imaged at varying kVp levels to determine the cross-scatter fraction and contrast-to-noise ratio (CNR). Monte Carlo simulations quantified the effect of the gantry angle on the cross-scatter fraction. A cadaver foot with implanted beads was also imaged. The effect of cross-scatter on marker-based tracking accuracy was investigated. Results demonstrated that the cross-scatter fraction varied from 0.15 for the 4-in. cylinder to 0.89 for the 10-in. cylinder when averaged across kVp. The average change in CNR due to cross-scatter ranged from 5% to 36% CNR decreases for the 4- and 10-in. cylinders, respectively. In simulations, the cross-scatter fraction increased with the gantry angle for the 8- and 10-in. cylinders. Cross-scatter significantly increased static-tracking error by 15%, 25%, and 38% for the 6-, 8-, and 10-in. phantoms, respectively, with no significant effect for the foot specimen. The results demonstrated submillimeter marker-based tracking for a range of phantom sizes, despite cross-scatter degradation.
© 2015 Society of Photo-Optical Instrumentation Engineers (SPIE) 2329-4302/2015/$25.00 © 2015 SPIE
Janelle A. Cross, Ben McHenry, and Taly G. Schmidt "Quantifying cross-scatter contamination in biplane fluoroscopy motion analysis systems," Journal of Medical Imaging 2(4), 043503 (23 October 2015). https://doi.org/10.1117/1.JMI.2.4.043503
Published: 23 October 2015
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fluoroscopy

Monte Carlo methods

Motion analysis

Imaging systems

Bone

Contamination

Signal detection

RELATED CONTENT

3D Monte Carlo modeling of the SEM Are there...
Proceedings of SPIE (September 16 2014)
Novel features of the x ray scatter profile that are...
Proceedings of SPIE (March 03 2006)
Human motion analysis and modeling
Proceedings of SPIE (June 02 2011)

Back to Top