1 July 1990 Multilayer coated concave diffraction grating resolution and efficiency in the extreme ultraviolet
Author Affiliations +
Recent advances in multilayer structures for the extreme ultraviolet now make it possible to construct diffraction gratings in the wavelength range below 350 Å, which can be used for precision measurements using normal incidence spectrometers. We report results from two such gratings, one with conventionally ruled blazed facets and the other with a holographically ruled sinusoidal surface. Both gratings are 1 m in radius, 1200 lines/mm coated with a molybdenum-silicon multilayer for use in the 150 Å wavelength region. A 1 m normal incidence spectrometer with a Garton flash tube source and a film detector was used to test the spectral resolution. Relative efficiency measurements were obtained by comparison to spectra produced by an osmium coated grating. Emission lines in the wavelength region of interest (characteristic of the source) are easily detected and well resolved with both multilayer coated gratings. Quantitative efficiency measurements were obtained using a Penning source coupled to a 1 m grazing incidence monochromator and an imaging photon counting detector.
Jay V. Bixler, Troy W. Barbee Jr., and Dan D. Dietrich "Multilayer coated concave diffraction grating resolution and efficiency in the extreme ultraviolet," Optical Engineering 29(7), (1 July 1990). https://doi.org/10.1117/12.55663
Published: 1 July 1990
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Diffraction gratings

Extreme ultraviolet

Back to Top