Presentation + Paper
11 September 2018 Dual-energy x-ray computed tomography scanner using a room-temperature cadmium-telluride detector and a range-region counter
Author Affiliations +
Abstract
To obtain two kinds of tomograms at two different X-ray energy ranges simultaneously, we have constructed a dualenergy (DE) X-ray photon counter with a room-temperature cadmium telluride (CdTe) detector. X-ray photons are detected using the CdTe detector system, and event pulses from an amplifier module are sent to three comparators simultaneously to determine three threshold energies of 33, 48 and 50 keV. The DE counter has energy-range and - region selectors, and the energy range and region are 33-48 and beyond 50 keV (50-100 keV); the maximum energy corresponds to the tube voltage. We performed DE computed tomography (DE-CT) using four lead pinholes at a tube voltage of 100 kV. In Gd-K-edge CT at a range of 50-100 keV, Gd media were observed at high contrasts. The spatial resolutions were 0.5×0.5 mm2, and the exposure time for DE-CT was 19.6 min at a total rotation angle of 360°. At a tube voltage of 100 kV and a current of 0.22 mA, the count rate was 36 kilocounts per second.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Manabu Watanabe, Eiichi Sato, Yasuyuki Oda, Sohei Yoshida, Hodaka Moriyama, Osahiko Hagiwara, Hiroshi Matsukiyo, Toshiyuki Enomoto, and Shinya Kusachi "Dual-energy x-ray computed tomography scanner using a room-temperature cadmium-telluride detector and a range-region counter", Proc. SPIE 10763, Radiation Detectors in Medicine, Industry, and National Security XIX, 1076302 (11 September 2018); https://doi.org/10.1117/12.2323756
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

Gadolinium

Scanners

X-ray computed tomography

Photon counting

Lead

RELATED CONTENT

Measurement of x ray spectra using a recent YAP(Ce) MPPC...
Proceedings of SPIE (September 07 2017)
Dual energy high count rate x ray computed tomography using...
Proceedings of SPIE (September 11 2018)
High speed tripe energy x ray photon counter using a...
Proceedings of SPIE (January 28 2019)
High speed dual energy x ray photon counter Using a...
Proceedings of SPIE (January 28 2019)
Monte Carlo study of x ray cross talk in a...
Proceedings of SPIE (June 05 2003)

Back to Top