11 September 2018 Triple-energy high-count-rate x-ray computed tomography scanner using a cooled cadmium-telluride detector
Author Affiliations +
Abstract
To obtain three kinds of tomograms at three different X-ray energy ranges simultaneously, we have constructed a triple-energy (TE) X-ray photon counter with a cooled cadmium telluride (CdTe) detector and three sets of comparators and microcomputers. X-ray photons are detected using the CdTe detector, and the event pulses produced using amplifiers are sent to three comparators simultaneously to regulate three threshold energies of 15, 33 and 50 keV. Using this counter, the energy ranges are 15-33, 33-50 and 50-100 keV; the maximum energy corresponds to the tube voltage. We performed TE computed tomography (TE-CT) at a tube voltage of 100 kV. Using four lead pinholes, three tomograms were obtained simultaneously. Iodine-K-edge CT was carried out utilizing an energy range of 33-50 keV. At a tube voltage of 100 kV and a current of 0.11 mA, the count rate was 21 kilocounts per second (kcps).
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hodaka Moriyama, Eiichi Sato, Yasuyuki Oda, Yuichi Sato, Sohei Yoshida, Satoshi Yamaguchi, Osahiko Hagiwara, Hiroshi Matsukiyo, Toshiyuki Enomoto, Manabu Watanabe, and Shinya Kusachi "Triple-energy high-count-rate x-ray computed tomography scanner using a cooled cadmium-telluride detector", Proc. SPIE 10763, Radiation Detectors in Medicine, Industry, and National Security XIX, 107630H (11 September 2018); https://doi.org/10.1117/12.2320172
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

Scanners

X-ray computed tomography

X-ray detectors

Photon counting

Arteries

RELATED CONTENT

Dual energy high count rate x ray computed tomography using...
Proceedings of SPIE (September 11 2018)
Dual energy x ray computed tomography scanner using a room...
Proceedings of SPIE (September 11 2018)
High speed tripe energy x ray photon counter using a...
Proceedings of SPIE (January 28 2019)
Investigation of low dose energy dispersive x ray computed...
Proceedings of SPIE (September 09 2019)
High speed dual energy x ray photon counter Using a...
Proceedings of SPIE (January 28 2019)
Monte Carlo study of x ray cross talk in a...
Proceedings of SPIE (June 05 2003)

Back to Top