Poster + Paper
10 October 2020 Variation of optical attenuation coefficient during ischemia-reperfusion process of rabbit kidney measured by optical coherence tomography
Author Affiliations +
Conference Poster
Abstract
Optical properties of biological tissue are key parameters of optical imaging, and also provide useful information of the tissues under different physiological conditions. The optical attenuation coefficient (OAC) related to the optical properties can be calculated from optical coherence tomography(OCT) data. OCT has the advantages of high-resolution and fast imaging speed, and can image the tissues in vivo and in real-time. Due to the lack of blood perfusion, renal ischemia is accompanied by changes in microstructure of the kidney, which the OAC is sensitive to. We applied OCT to detect the OAC variation during ischemia-reperfusion process of rabbit kidney, and further estimated the ischemiareperfusion (I/R) injury. In order to study the temporal relationship between I/R injury and ischemia, 12 New Zealand rabbits were divided averagely into 4 groups (ischemia 30/60/90/120 min group). The kidneys were observed in vivo using a spectral domain OCT (SD-OCT) which light source centered at 900 nm. Three-dimensional OCT images of the kidney were obtained before the occlusion of renal artery and several time points after the blood reperfusion. The OAC were obtained by exponential fitting of OCT A-lines. Mapping attenuation coefficient (MAC) of each 3D OCT data set was performed to get the attenuation coefficient distribution in the kidney. The OAC curve with reperfusion time showed that the OAC was sensitive to ischemia and helpful for the estimation of ischemia-reperfusion injury. The distribution of attenuation coefficient in MAC image could reflect the local status of kidney.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yuhong Fang, Wei Gong, Zheng Huang, Tao Li, Xiang Wu, Qingjiang Xu, Deyuan Yang, and Shusen Xie "Variation of optical attenuation coefficient during ischemia-reperfusion process of rabbit kidney measured by optical coherence tomography", Proc. SPIE 11553, Optics in Health Care and Biomedical Optics X, 115532R (10 October 2020); https://doi.org/10.1117/12.2575207
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical coherence tomography

Kidney

Tissue optics

Signal attenuation

Ischemia

Optical testing

Injuries