13 July 2022 Breast shape estimation and correction in CESM biopsy
Author Affiliations +
Proceedings Volume 12286, 16th International Workshop on Breast Imaging (IWBI2022); 122860H (2022) https://doi.org/10.1117/12.2625779
Event: Sixteenth International Workshop on Breast Imaging, 2022, Leuven, Belgium
Abstract
Description of purpose Contrast-enhanced spectral mammography can be used to guide needle biopsies. However, in vertical approach the compressed breast is deformed generating a so-called bump in the paddle aperture, which may interfere with the visibility of contrast-uptakes. Local thickness estimation would provide an enhanced image quality of the recombined image, increasing the visibility of the contrast-uptakes to be targeted during the biopsy procedure. In this work we propose a method to estimate the shape of the breast bump in biopsy vertical approach. Materials and Methods Our method consists on two steps: first, we compute a raw thickness which does not take into account the presence of contrast-uptakes; second, we use a physical model to separate the sparse iodine texture from the breast shape. This physical model is composed by a sum of Fourier components, describing the main shape of the bump, a series of low-order polynomials, describing the main compressed thickness, paddle tilt and deflection, and non-linear components describing the translation and rotation of the paddle aperture. A 3D object mimicking a bump was fabricated to test the pertinence of our shape model. Also, clinical images of 21 patients which followed CESM-guided biopsy were visually assessed. Results Comparison between raw and final estimated thickness of our 3D test object shows an error standard deviation of 0.37 mm similar to the noise standard deviation equals to 0.32 mm. The visual assessment of clinical cases showed that the thickness correction removes the superimposed low-frequency pattern due to non-uniform thickness of the bump, improving the identification of the lesion to be targeted. Conclusion The proposed method for thickness estimation is adapted to CESM-guided biopsies in vertical approach and it improves the identification of the contrast-uptakes that need to be targeted during the procedure.
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ruben Sanchez De La Rosa, Clément Jailin, Ann-Katherine Carton, Pablo Milioni, Laurence Casteignau, and Serge Muller "Breast shape estimation and correction in CESM biopsy", Proc. SPIE 12286, 16th International Workshop on Breast Imaging (IWBI2022), 122860H (13 July 2022); https://doi.org/10.1117/12.2625779
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Breast

Biopsy

Biological research

Image quality

Iodine

X-rays

X-ray imaging

Back to Top