Paper
20 April 2000 Micro-CT image-derived metrics quantify arterial wall distensibility reduction in a rat model of pulmonary hypertension
Roger H. Johnson, Kelly L. Karau, Robert C. Molthen, Steven T. Haworth, Christopher A. Dawson
Author Affiliations +
Abstract
We developed methods to quantify arterial structural and mechanical properties in excised rat lungs and applied them to investigate the distensibility decrease accompanying chronic hypoxia-induced pulmonary hypertension. Lungs of control and hypertensive (three weeks 11% O2) animals were excised and a contrast agent introduced before micro-CT imaging with a special purpose scanner. For each lung, four 3D image data sets were obtained, each at a different intra-arterial contrast agent pressure. Vessel segment diameters and lengths were measured at all levels in the arterial tree hierarchy, and these data used to generate features sensitive to distensibility changes. Results indicate that measurements obtained from 3D micro-CT images can be used to quantify vessel biomechanical properties in this rat model of pulmonary hypertension and that distensibility is reduced by exposure to chronic hypoxia. Mechanical properties can be assessed in a localized fashion and quantified in a spatially-resolved way or as a single parameter describing the tree as a whole. Micro-CT is a nondestructive way to rapidly assess structural and mechanical properties of arteries in small animal organs maintained in a physiological state. Quantitative features measured by this method may provide valuable insights into the mechanisms causing the elevated pressures in pulmonary hypertension of differing etiologies and should become increasingly valuable tools in the study of complex phenotypes in small-animal models of important diseases such as hypertension.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Roger H. Johnson, Kelly L. Karau, Robert C. Molthen, Steven T. Haworth, and Christopher A. Dawson "Micro-CT image-derived metrics quantify arterial wall distensibility reduction in a rat model of pulmonary hypertension", Proc. SPIE 3978, Medical Imaging 2000: Physiology and Function from Multidimensional Images, (20 April 2000); https://doi.org/10.1117/12.383413
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Lung

Image segmentation

Pulmonary hypertension

Point spread functions

Arteries

3D metrology

3D image processing

Back to Top