Paper
25 March 2008 Photodiode forward bias to reduce temporal effects in a-Si based flat panel detectors
Author Affiliations +
Abstract
Lag and sensitivity modulation are well known temporal artifacts of a-Si photodiode based flat panel detectors. Both effects are caused by charge carriers being trapped in the semiconductor. Trapping and releasing of these carriers is a statistical process with time constants much longer than the frame time of flat panel detectors. One way to reduce these temporal artifacts is to keep the traps filled by applying a pulse of light over the entire detector area every frame before the x-ray exposure. This paper describes an alternative method, forward biasing the a-Si photodiodes and supplying free carriers to fill the traps. The array photodiodes are forward biased and then reversed biased again every frame between the panel readout and x-ray exposure. The method requires no change to the mechanical construction of the detector, only minor modifications of the detector electronics and no image post processing. An existing flat panel detector was modified and evaluated for lag and sensitivity modulation. The required changes of the panel configuration, readout scheme and readout timing are presented in this paper. The results of applying the new technique are presented and compared to the standard mode of operation. The improvements are better than an order of magnitude for both sensitivity modulation and lag; lowering their values to levels comparable to the scintillator afterglow. To differentiate the contribution of the a-Si array, from that of the scintillator, a large area light source was used. Possible implementations and applications of the method are discussed.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ivan Mollov, Carlo Tognina, and Richard Colbeth "Photodiode forward bias to reduce temporal effects in a-Si based flat panel detectors", Proc. SPIE 6913, Medical Imaging 2008: Physics of Medical Imaging, 69133S (25 March 2008); https://doi.org/10.1117/12.769951
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photodiodes

Sensors

Amorphous silicon

Modulation

Capacitors

Amplifiers

Transistors

RELATED CONTENT

High-performance 480x12x4 linear CMOS IR multiplexer
Proceedings of SPIE (October 26 1999)
Amorphous silicon x-ray image sensor
Proceedings of SPIE (April 11 1996)
A low light level sensor with dark current compensating pixels
Proceedings of SPIE (September 27 2008)
MInOSS project
Proceedings of SPIE (December 19 1996)

Back to Top