24 July 2014 Performance improvement of x-ray CCDs by applying a magnetic field
Author Affiliations +
Abstract
X-ray CCDs are widely used as the focal plane detectors of the X-ray telescopes. Among them, backside illuminated CCDs with a deep depletion layer are preferred because of their high quantum efficiency in both soft and hard X-ray bands. However, they tend to have poorer energy resolution and higher background due to the relatively large charge diffusion. We carried out simple experiments to apply a magnetic field of 0.25 T or 0.4 T to the CCD, which is expected to suppress the charge diffusion very slightly and to bring subtle improvement in the performance of the CCD. We found unexpectedly that grade branching ratios of Grade 3 and Grade 4, both are horizontal split events, symmetrically changed depending on the direction of the applied magnetic field. Although the cause of the change is not understand yet, it clearly demonstrate that the charge cloud in the CCD is affected by the externally applied magnetic field. We also found a decrease of Grade 7 only in the experiment 2. We consider this may be caused by the supress of the charge diffusion by the magnetic field, although other possibilities can not be excluded. No significant improvement was detected in the energy resolution. We could show with these experiments that the charge cloud in the CCD may be controlled by the externally applied magnetic field. Magnetic field may become useful tool in future to improve the performance of CCDs.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Keisuke Kondo, Tadayasu Dotani, Masanobu Ozaki, and Masachika Iwai "Performance improvement of x-ray CCDs by applying a magnetic field", Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91443W (24 July 2014); https://doi.org/10.1117/12.2055705
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetism

Charge-coupled devices

X-rays

Diffusion

X-ray telescopes

Data modeling

Quantum efficiency

RELATED CONTENT

Upgrade of the thirty meter x ray pencil beam line...
Proceedings of SPIE (July 24 2014)
Ground based x ray calibration of the Astro H soft...
Proceedings of SPIE (July 24 2014)
Absolute timing with the SWIFT X-ray telescope (XRT)
Proceedings of SPIE (August 18 2005)
CCD development and characterization for the GOES N and O...
Proceedings of SPIE (October 22 1999)
Frame store PN-CCD detector for the ROSITA mission
Proceedings of SPIE (March 11 2003)
Focal plane CCD camera for the X Ray Telescope (XRT)...
Proceedings of SPIE (October 12 2004)

Back to Top