Fourier single-pixel imaging (FSI) has been proven to achieve excellent image quality when sampling all information in the Fourier domain. However, when the size of an imaging target is large, fully sampling Fourier coefficients would result in a large waste of sampling resources. An adaptive sampling method is proposed that is simple to implement and effectively improves the reconstructed image quality from undersampled Fourier coefficients. Through a rough estimation of spectrum energy distribution, the adaptive sampling trajectory is generated by the designed adaptive probability density function. Both the results of computational simulations and experiments demonstrate that the proposed method has overcome the limitations of the insufficient sampling rates, and the reconstruction images have obtained dramatic improvements. These improvements greatly promote the development of the FSI during undersampled conditions.
Correlated imaging is a research hotspot in recent years. It shows advantages over conventional optical imaging on scanning and imaging rate, noise immunity and so on, and has good application prospects in military electronic reconnaissance and other fields According to the basic principle of polarization correlation imaging, this paper established the spectral polarization BRDF model of rough surface. Taking two typical materials of aluminum alloy and PC plastic as target and background, the effects of wavelength on polarization correlated imaging of rough surface objects is analyzed. Theoretical analysis and simulation results show that the wavelength has little influence on the conventional correlated imaging, and the effects on the polarization correlated imaging appear in complex refractive index, linear polarization and contrast. The wavelength of the best imaging quality can be determined according to different material properties of the set target and the known background.
Compressive sensing ghost imaging (CSGI) is an imaging mechanism that can nonlocally obtain an unknown object’s information with a single-pixel detector by the correlation of intensity fluctuations. In the practical research and application of CSGI, object detection plays a crucial role in real-time monitoring and dynamic optimization of speckle pattern. We demonstrate, for the first time to our knowledge, how to solve the low-resolution and undersampling problems in CSGI object detection. The method we use is to combine generative adversarial networks (GANs) with object detection systems. The robustness of the object detection model can increase by generating reconstructed images of different resolutions and sampling rates for training. The experiment results have verified that the mean average precision of CSGI object detection using GANs has been improved 16.48% and 2.98% on MSCOCO 2017 compared with two traditional learning methods, respectively.
Ghost imaging is an imaging mechanism that can non-locally obtain an unknown object’s information with a single-pixel detector by the correlation of intensity fluctuations. To overcome the drawback of polarization compressive ghost imaging (PCGI), here we develop a novel adaptive polarization compressive ghost imaging (APCGI) method. By performing principal component analysis of the polarization statistics, we can compute the optimum unequal weighting coefficients forming as linear combinations of the light into bucket detectors. The specific steps of APCGI include calculating complete polarization parameters on the background, performing principal components analysis for optimal parameters, obtaining the information on the target-with-background scene. Experimental results demonstrate that adaptive polarization compressive ghost imaging performs better in restraining the background and pop out the details of targets as well as obtains better image quality.
As a new imaging mechanism, ghost imaging has become a hot area of research in optical imaging field. In this paper, the effect of intensity correlation order on lensless ghost imaging system is investigated. We demonstrate that the image quality of Nth-order ghost imaging and Nth-order ghost imaging with background subtraction can be affected by the different intensity correlation order of test light and reference both theoretically and experimentally. The result indicates that the image quality will not be certainly increased with the increasing of the intensity correlation order, and here will be very useful for choosing an appropriate intensity correlation order in practice.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.