We have developed a novel x-ray interferometer, multi-image x-ray interferometer module (MIXIM), comprised of a fine aperture mask and an x-ray detector. The angular resolution of this system can be improved with an increase of the distance between two components or a decrease of the aperture size. Although MIXIM has already achieved an angular resolution of less than 0.1” by applying the Talbot effect with a periodic multi-pinhole mask, there remains the issue that its low opening fraction of 1.3% decreases the effective area of the imaging system. Therefore, we newly introduced periodic coded aperture masks which have opening fractions of about 50% instead of the multi-pinhole mask. Conducting an experiment with a 12.4 keV parallel x-ray beam, we successfully demonstrated that the periodic coded aperture could form the self-image, and obtained the x-ray source profile with sub-arcsecond angular resolution by deciphering the coded pattern. The effective area increases about 25 times compared with the multi-pinhole mask by the introduction of the periodic coded aperture masks, which indicates that this novel method can be effective for addressing the problem.
We intoduce our novel method of super high resolution astronomical X-ray imaging, Multi Image X-ray Interferometer Method, Modules, Missions (MIXIM). In series of experiments on the ground we not only verified the concept of MIXIM but also realized 2D imaging with angular resolution better than 0. ′′1. Employment of small pixel size CMOS sensor was the key to this achievement. Scalability is also an important feature of MIXIM., and various mission format is available. We show some examples from a very small satellite for sub arcsecond resolution to a formation flight with a millions km separation to gain µas resolution. MIXIM is different from X-ray mirrors in various points, for example, it does not have a collecting power. Considering the limitations and advantages of MIXIM, we should choose bright apparently point-like sources as targets. Nearby AGNs are primary ones, and the MIXIM scope just corresponds to spatial scales which have not yet resolved in X-rays.
CFRP is a composite material composed of carbon fiber and resin. CFRP is commonly applied to the aerospace industry which requires lightweight and intensity. Thanks to superior formability of CFRP, we can form shape of Wolter-1 optics, which consists of paraboloid and hyperboloid, to a monolithic substrate. Since the surface roughness of a CFRP substrate is a few µm, we have to make the smooth surface for reflecting X-rays on the CFRP substrate. We have developed a new method of shaping the reflective surface instead of the replica method used in lightweight X-ray mirrors such as Astro-H. In the new method, the reflective surface is formed by pasting thin sheet-glasses with 100 µm thick onto the CFRP substrate. The thin sheet-glass has a surface roughness about 0.4 nm as measured by Zygo. We fabricated a CFRP mirror pasting thin sheet-glasses, and then coated tungsten on the mirror in June 2020. The figure error (s) of the CFRP mirror was achieved to be about 1-2 μm by stacking the CFRP mirror on the housing module. X-ray imaging quality of the CFRP mirror was measured at Spring-8 in July 2020. The half-power diameter of the CFRP mirror was estimated to be about 150 arcsec, which was nearly equal to the prediction from a distribution of the slope error deduced from the surface profile. We describe a future plan to improve the image quality of the CFRP mirror.
We have proposed a new style X-ray interferometer, Multi-Image X-ray Interferometer Module (MIXIM), to achieve high angular resolution. MIXIM is comprised of a grating and an X-ray detector, and its angular resolution is in inverse proportion to the distance between two components. Although we have already detected a 1D interference fringe which corresponds an angular resolution of about 1” in our past experiment, its amplitude is not so high partly because of the lack of the spatial resolution of the X-ray detector. Then we newly adopt a CMOS detector which has both high spatial resolution (< 2.5 μm) and high spectroscopic capability (FWHM∼ 170 eV @5.9 keV) and evaluate the performance of MIXIM at BL20B2 in SPring-8, the synchrotron radiation facility in Japan. 1D interference fringes in this experiment have much higher amplitudes than those in the past experiment, which demonstrates the improvement of the performance due to the new CMOS detector. We also introduce a 2D grating for the first time, and try to obtain the 2D profile of the X-ray beam of which the size is 0.28” (H) and 0.06” (V). Extending the distance between two components to 866.5 cm, 2D imaging by MIXIM succeeds in capturing the horizontally elongated beam structure. The angular resolution at this configuration is calculated to be 0.076”, which is the highest ever achieved for astronomical X-ray imagers.
X-Ray Imaging and Spectroscopy Mission (XRISM) is the seventh Japanese X-ray astronomical satellite scheduled to be launched in the Japanese fiscal year 2022. XRISM has two mission instruments, “Resolve”, a soft X-ray spectrometer, and “Xtend”, a soft X-ray imager. The Former is an X-ray micro-calorimeter that has ∼ 5 eV of energy resolution with 3′ × 3 ′ of field of view. The Latter is an X-ray CCD camera with 38′ × 38′ of field of view. Both instruments are placed on the focal plane of X-ray telescopes, X-ray Mirror Assembly (XMA). Xtend CCDs are designed almost the same as those of Hitomi (ASTRO-H), whereas some improvements have been applied. In 2019, flight-model (FM) candidates of Xtend CCDs were fabricated by Hamamatsu Photonics K.K. We performed screening experiments to examine whether they met requirements or not, and then selected the best four chips as the FM. We then performed on-ground calibration on August 2019 and September 2019 for the FM chips to determine the gain correction parameters and to construct the detector response with several energies of monochromatic X-ray. In this paper, we report screening, selection, and on-ground calibration processes, especially focusing on the response verification.
We report current status of developing Soft X-ray Imager (SXI), the X-ray CCD camera onboard X-Ray Imaging and Spectroscopy Mission (XRISM). Four flight model (FM) CCDs have been selected considering several items including energy resolution at 5.9keV, CTI, dark current, etc. We have also completed calibration campaign for all the FM CCDs. Initial analyses show that the response function for monochromatic X-rays is basically the same as that of Hitomi CCDs. The focal plane including the single-stage Stirling cooler has been assembled. Production of key parts in SXI sensor body such as contamination blocking filter and onboard calibration source has been finished and they are waiting for assemble. The digitized signals of the CCD are corrected step by step before conversion to X-ray energy. We are preparing calibration database for the correction such as CTI, gain, and line redistribution function.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.