The imaging x-ray polarimetry explorer (IXPE) was launched on December 9, 2021, from Cape Canaveral into a low-Earth equatorial orbit. The mission, led by NASA in collaboration with the Italian Space Agency (ASI), features three identical telescopes, each with an imaging x-ray photoelectric polarimeter at the focus of an x-ray mirror assembly. Each focal-plane detector includes a set of four calibration sources powered by a 55Fe nuclide to monitor the detector’s performance. Of these sources, one produces polarized x-rays at two energies and the remaining three generate unpolarized radiation. Here we present the status of this monitoring program, starting from installation of the flight nuclides before on-ground environmental testing of the observatory through recent on-orbit measurements during science operations.
The NASA/ASI imaging x-ray polarimetry explorer, which will be launched in 2021, will be the first instrument to perform spatially resolved x-ray polarimetry on several astronomical sources in the 2- to 8-keV energy band. These measurements are made possible owing to the use of a gas pixel detector (GPD) at the focus of three x-ray telescopes. The GPD allows simultaneous measurements of the interaction point, energy, arrival time, and polarization angle of detected x-ray photons. The increase in sensitivity, achieved 40 years ago, for imaging and spectroscopy with the Einstein satellite will thus be extended to x-ray polarimetry for the first time. The characteristics of gas multiplication detectors are subject to changes over time. Because the GPD is a novel instrument, it is particularly important to verify its performance and stability during its mission lifetime. For this purpose, the spacecraft hosts a filter and calibration set (FCS), which includes both polarized and unpolarized calibration sources for performing in-flight calibration of the instruments. We present the design of the flight models of the FCS and the first measurements obtained using silicon drift detectors and charge-coupled device cameras, as well as those obtained in thermal vacuum with the flight units of the GPD. We show that the calibration sources successfully assess and verify the functionality of the GPD and validate its scientific results in orbit; this improves our knowledge of the behavior of these detectors in x-ray polarimetry.
IXPE scientific payload comprises of three telescopes, each composed of a mirror and a photoelectric polarimeter based on the Gas Pixel Detector design. The three focal plane detectors, together with the unit which interfaces them to the spacecraft, are named IXPE Instrument and they will be built and calibrated in Italy; in this proceeding, we will present how IXPE Instrument will be calibrated, both on-ground and in-flight. The Instrument Calibration Equipment is being finalized at INAF-IAPS in Rome (Italy) to produce both polarized and unpolarized radiation, with a precise knowledge of direction, position, energy and polarization state of the incident beam. In flight, a set of four calibration sources based on radioactive material and mounted on a filter and calibration wheel will allow for the periodic calibration of all of the three IXPE focal plane detectors independently. A highly polarized source and an unpolarized one will be used to monitor the response to polarization; the remaining two will be used to calibrate the gain through the entire lifetime of the mission.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.