In preparation for the Dark Energy Spectroscopic Instrument (DESI), a new top end was installed on the Mayall 4-meter telescope at Kitt Peak National Observatory. The refurbished telescope and the DESI instrument were successfully commissioned on sky between 2019 October and 2020 March. Here we describe the pointing, tracking and imaging performance of the Mayall telescope equipped with its new DESI prime focus corrector, as measured by six guider cameras sampling the outer edge of DESI’s focal plane. Analyzing ~500,000 guider images acquired during commissioning, we find a median delivered image FWHM of 1.1 arcseconds (in the r-band at 650 nm), with the distribution extending to a best-case value of ~0.6 arcseconds. The point spread function is well characterized by a Moffat profile with a power-law index of β ≈ 3.5 and little dependence of β on FWHM. The shape and size of the PSF delivered by the new corrector at a field angle of 1.57 degrees are very similar to those measured with the old Mayall corrector on axis. We also find that the Mayall achieves excellent pointing accuracy (several arcseconds RMS) and minimal open-loop tracking drift (< 1 milliarcsecond per second), improvements on the telecope’s pre-DESI performance. In the future, employing DESI’s active focus adjustment capabilities will likely further improve the Mayall/DESI delivered image quality.
We characterize the response of a novel 250 µm thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable, single-electron resolution with readout noise σ 0.18 e− rms/pix from 400 non-destructive measurements of the charge in each pixel. We verify that the gain derived from photon transfer curve measurements agrees with the gain calculated from the quantized charge of individual electrons to within < 1%. We also perform relative quantum efficiency measurements and demonstrate high relative quantum efficiency at optical/near- infrared wavelengths, as is expected for a thick, fully depleted detector. Finally, we demonstrate the ability to perform multiple non-destructive measurements and achieve sub-electron readout noise over configurable sub- regions of the detector. This work is the first step toward demonstrating the utility of Skipper CCDs for future astronomical and cosmological applications.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.